Pure sine wave solar inverter(on/of Grid).
Output power factor 1.0.
WIFI&GPRS available for IOS and Android.
Inverter can run without battery.
One-key restoration to factory settings .
Built-in Lithium battery automatic activation.
Built-in 120A MPPT Solar charge:Max 6200W(for 3.6KW/4.2KW),Max 6500W(for 6.2KW)
High PV input voltage range(60 ~ 500VDC).
Built-in anti-dust kit for harsh environment.
Smart battery charge design to optimize battery life.
Dual output.
Dual communication ports for Battery communicationand Wifi communication
| MODEL | CCH 4.2W | CCH 6.2W |
| Phase | 1-phase | |
| Maximum PV Input Power | 6200W | 6500W |
| Rated Output Power | 4200W | 6200W |
| Maximum Solar Charging Current | 120A | |
| GRID-TIE OPERATION | ||
| PV INPUT(DC) | ||
| Nominal DC Voltage/Maximum Current | 360/500VDC | |
| Stat-up Voltage/Initial Feeding Voltage | 60VDC/90VDC | |
| MPPT Voltage Range | 90-450VDC | |
| Maximum Input Current | 1/18A | 2/22A |
| GRID OUTPUT(AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Voltage Range | 195.5-253VDC | |
| Nominal Output Current | 18.2A | 27.0A |
| Power Factor | >0.99 | |
| EFFICIENCY | ||
| Maximum Conversion Efficiency(DC/AC) | 0.98 | |
| TWO LOAD OUTPUT POWER | ||
| Full Load | 4200W | 6200W |
| Maxium MainLoad | 4200W | 6200W |
| Maxium Second Load(battery mode) | 1400W | 2067W |
| Maxium Load Cut Off Voltage | 26VDC | 52VDC |
| Maxium Load Return Voltage | 27VDC | 54VDC |
| OFF-GRID OPERATION | ||
| AC INPUT | ||
| AC Start-up Voltage/Auto Restart Voltage | 120-140VAC/180VAC | |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Frequency Range | 59~61+1HZ | |
| Maxium AC Input Current | 24.7A | 36.7A |
| PV INPUT(DC) | ||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | |
| MPPT Voltage Range | 60-450VDC | |
| Maximum Input Current | 1/18A | 1/22A |
| BATTERY MODE OUTPUT(AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Waveform | Pure sine wave | |
| Efficiency(DC to AC) | 94% | |
| BATTERY & CHARGER | ||
| Nominal DC Voltage | 24VDC | 48VDC |
| Maximum Solar Charging Current | 120A | |
| Maximum AC Charging Current | 100A | |
| Maximum Charging Current | 120A | |
| HYBRID OPERATION | ||
| PV INPUT(DC) | ||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | |
| Stat-up Voltage/Initial Feeding Voltage | 90VDC/120VDC | |
| MPPT Voltage Range | 60-450VDC | |
| Maximum Input Current | 1/18A | 1/22A |
| GRID OUTPUT(AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Voltage Range | 195.5-253VDC | |
| Nominal Output Current | 18.2A | 27.0A |
| AC INPUT | ||
| AC Start-up Voltage/Auto Restart Voltage | 120-140VAC/180VAC | |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Maximum Input Current | 24.7A | 36.4A |
| Maximum AC Charging Current | 100A | |
| GENERAL | ||
| PHYSICAL | ||
| Dimension,D*W*H(mm) | 420*350*145 | |
| Carton Dimension,D*W*H(mm) | 500*415*215 | |
| Net Weight(kgs) | 8 | 8.9 |
| Gross Weight(kgs) | 9 | 10 |
| INTERACE | ||
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | |
| ENVIRONMENT | ||
| Humidity | 5% to 95% Relative Humidity(Non-condensing) | |
| Operationg Temperature | -10℃-50℃ | |
| STANDARD | ||
| Compliance Safety | CE | |